DUAL CHANNEL COUNTER/PROCESS MONITOR

FEATURES

SPECIFICATIONS

ANALOG INPUTS:
i) J,K,T,E,R,S,B Thermocouples, Thermistor, RTD
ii) 4-20milliamp iii) 0-10vdc, 0-5vdc iv) 0-100 millivolt
Cold junction error: +/- 1 C (10C to 45c)
Open thermocouple indication: HELP displayed
ACCURACY:
Temperature resolution: 1C/1F
Voltage = 0.05% FS Current = 0.05% FS
ANALOG TO DIGITAL CONVERSION
Dual Slope, integrating, 20,000 count A/D converter
Conversion rate: 7 conversions/sec (typical)
SCALE/OFFSET (Programmable):
Scale: 1 - 30000 Offset : 0 - 20.00 (current),
0 - 10.000 (voltage), 0 - 100.00 (millivolt)
DECIMAL POINT: None, 10th, 100th & 1000th position.
PULSE/SQUARE WAVE INPUTS:
0-5vdc pulse or square wave (Schmitt Trigger on input)
Input Low = 0.0vdc minimum 0.6vdc, maximum
Input high = 2.5vdc, minimum 5.0vdc, maximum
RPM range: 1 - 999,999 revolutions per minute
COUNT range: 1 - 9,999,999
RATE range: Varies with time base -- 9,999,999 max.
Time base for rate: 100 milliseconds to 9,999.999 Sec.
High frequency range: 1 Hz to 1 megahertz
Low frequency range: 2.00Hz to 5000.00Hz.
DISPLAY: Red, 7-seg LED displays (Seven), 0.39” Height
Negative polarity and Over-range indication.
DISPLAY TEST: 8.8.8.8.8.8.8. on power up
POWER OPTION
120VAC (60 Hz) (Standard) 220VAC (50 Hz) (Optional)
8VDC -- 15VDC @ 900ma (optional)
OUTPUT (optional)
1.Open collector - 4 open collector outputs, maximum
sink capability of 50ma per output
2.Relays: Single pole single throw, 1 Amp @ 28Vdc or
0.5 Amp @ 120Vac resistive
Output termination: Euro-style plugable connector